top of page

Boosting UPS Performance through Input and Output Monitoring

UPS monitoring.png
Picture1_edited.jpg

A large data center relied on Uninterruptible Power Supplies (UPS) to ensure a continuous power supply during outages and protect critical equipment. While the existing UPS systems were adequate, the facility experienced periodic issues with power reliability. Voltage drops, power surges, and current fluctuations at both the input and output of the UPS occasionally led to equipment malfunctions, operational delays, and unplanned maintenance costs.

To address these concerns, the data center needed a more comprehensive monitoring solution to track the UPS’s performance in real time. Truewatts worked with the customer to design a monitoring system that could simultaneously measure voltage and current at both the input and output of the UPS, offering a clear view of power quality, system efficiency, and potential issues.

The Solution: Input and Output Monitoring System

Truewatts implemented a dual-point monitoring system that simultaneously   tracked the voltage and current at the input (from the grid) and output (to the critical load) of the UPS. The system provided real-time data on the following parameters:

  • Input Monitoring: Voltage stability, current fluctuations, and power factor from the grid to ensure the UPS was receiving consistent and reliable power.

  • Output Monitoring: Voltage and current levels supplied to critical equipment, ensuring that the UPS was delivering clean, stable power, even during disturbances like outages or grid failures.

This real-time data was fed into a centralized dashboard, providing instant alerts for any deviations or anomalies, such as over-voltage, under-voltage, or current imbalances.

Benefits of UPS Input and Output Monitoring

  1. Enhanced Power Quality: Monitoring both input and output ensured that the UPS was delivering high-quality power to sensitive equipment. Any power quality issues, such as sags, surges, or harmonic distortion at the input, could be detected and corrected before they impacted the UPS’s performance or the load it was protecting.

  2. Increased System Reliability: Simultaneous monitoring provided early warning of any potential UPS failures or inefficiencies. For example, if input power was unstable, the system would alert operators, allowing them to investigate grid-side issues before they caused UPS malfunctions.

  3. Improved Efficiency: The dual-point monitoring system helped identify inefficiencies at both the input and output, such as power losses due to poor power factor or voltage imbalances. By identifying these inefficiencies, the facility could optimize power consumption and improve the overall efficiency of its UPS systems.

  4. Proactive Maintenance: Real-time data enabled predictive maintenance by highlighting patterns of electrical fluctuations or load imbalances that could lead to UPS component wear or failure. Early detection of these issues allowed for timely maintenance, reducing the risk of unexpected downtime.

  5. Cost Savings: By ensuring consistent power quality and early detection of potential issues, the data center reduced the risk of equipment damage and unplanned outages, leading to lower operational and maintenance costs.

 

Conclusion

By implementing input and output monitoring for their UPS systems, the data center significantly improved its power reliability and efficiency. The ability to track real-time voltage and current at both the grid and critical load points allowed for a more proactive approach to power management, reducing the risk of outages, protecting sensitive equipment, and ultimately lowering costs.

bottom of page